The main function of the patch terminal
Protect the thin chemical copper just deposited to prevent it from being etched by acid, and thicken it to a certain extent through electroplating. Provide sufficient conductivity, thickness and prevent heating and mechanical defects in the conductive circuit.
Process parameters for copper electroplating of patch terminals: The main components of the bath are copper sulfate and sulfuric acid. A high-acid, low-copper formula is used to ensure the uniformity of the thickness distribution of the board surface during electroplating and the deep plating ability of deep holes; the sulfuric acid content is mostly between 180 and 240 g/L; the copper sulfate content is generally around 75 g/L, and there may be trace amounts of chloride ions in the bath, which serve as auxiliary gloss agents and copper light agents to jointly exert the gloss effect; the amount of copper light agent added is 3~5mI, and the addition of copper light agent is generally supplemented according to the kiloampere-hour method or according to the actual production board effect; the current for full-board electroplating is generally calculated as 2 amperes/square decimeter multiplied by the electroplatable area on the board; the temperature of the copper cylinder is generally controlled at 22~32 degrees.
Patch terminals can also be plated with copper, nickel, gold, palladium nickel, tin-lead, silver, etc. Different coatings have different performance characteristics.